Document · CMS calculator

IET Guidance Note 1, Appendix A

published

cms.doc.gn1

The IET's Guidance Note 1, Appendix A: the space factors for trunking and duct, the trunking capacity factors (Table A6), and the cable and conduit factors for conduit (Tables A1 to A4). Cited only: IET copyright, never reproduced here.

Local graph

Leans on · 0Leaned on by · 3NothingCMS capacity workbook — used to derive · Table A6’s trunking factors ÷ 45 %, publishedCMS capacity workbookused to derive · Table A6’strunking factors ÷ 45 %Conduit and cable factors — transcribed into · Tables A1–A4, publishedConduit and cable factorstranscribed into · Tables A1–A4Space factor — used to derive · Appendix A, publishedSpace factorused to derive · Appendix AIET Guidance Note 1,Appendix A Leans on · 0Leaned on by · 3NothingCMS capacity workbook — used to derive · Table A6’s trunking factors ÷ 45 %, publishedCMS capacityworkbookused to derive ·Table A6’s trunkingfactors ÷ 45 %Conduit and cable factors — transcribed into · Tables A1–A4, publishedConduit and cablefactorstranscribed into ·Tables A1–A4Space factor — used to derive · Appendix A, publishedSpace factorused to derive ·Appendix AIET GuidanceNote 1,Appendix A Leans on · 0Leaned on by · 3NothingCMS capacity workbook — used to derive · Table A6’s trunking factors ÷ 45 %, publishedCMS capacityworkbookused to derive ·Table A6’strunking factors ÷45 %Conduit and cable factors — transcribed into · Tables A1–A4, publishedConduit andcable factorstranscribed into ·Tables A1–A4Space factor — used to derive · Appendix A, publishedSpace factorused to derive ·Appendix AIET Guidance Note 1, AppendixA

publishedestimateda choiceno sourceArrows: the way the data flows

See it in the whole calculator

The original document

Publisher
The Institution of Engineering and Technology
Title
Guidance Note 1: Selection & Erection
Edition
as held: ISBN 9781785614477; the current edition is the 10th (BS 7671:2018+A4:2026)
Where in it
Appendix A — the space factors; Table A6 (trunking); Tables A1–A4 (conduit)
Do we hold it
Sparkline’s copy
May it be reproduced here
No. IET copyright — cited, never reproduced. Get it from the IET.

IET shop — Guidance Note 1 ↗ We are not the source of record.

How the calculator uses it

It is behind the space factor, the trunking areas and the conduit factors. Where a table is derived from it, the pages show only the values a real calculation used.

Watch for

The copy held is Sparkline's; the current edition is the 10th, aligned with BS 7671 Amendment 4. Check Appendix A against it.